3.2.2.2. Oil replacementRemove a drain stopper with a washer.
Merge oil in a suitable container.
Establish a new washer and a drain stopper.
Moment of an inhaling of 40-58 N · m.
Remove an opening stopper for control of level of oil and add oil of the same type to edge of an opening.
Filling volume (approximate quantity): 2.87 l.