2.13.3. Removal and installation of the sensor of provision of a butterfly valveUncover the rechargeable battery.
Disconnect a negative wire from the rechargeable battery.
Perform the following procedure for ensuring convenience of access.
Remove the air filter.
Remove an air hose.
|
Fig. 2.343. Removal of the sensor of provision of a butterfly valve
|
Remove the sensor of provision of a butterfly valve (fig. 2.343).
Make sure that the butterfly valve is completely closed.
Install the sensor of provision of a butterfly valve on a throttle branch pipe.
Inhaling moment: 1,6–2,4 N · m.
Make sure that the butterfly valve moves smoothly.
Connect the socket of the sensor of provision of a butterfly valve.
Make sure that tension of an output signal of the sensor of provision of a butterfly valve (PID WDS: the provision of a butterfly valve) – within norm when the gate is open or closed.
If does not meet standard, check the sensor of provision of a butterfly valve.
|